UPS Zircon ZC-MP 6kVA 1:1p

True Online Double Conversion In: 220V, 1p, Out:220V, 1p Type : Tower Back up time 7-10Mins

รายละเอียดเพิ่มเติม

ราคาปกติ : 73,590 บาท

ราคาพิเศษ : 69,000 บาท
( Excluded Vat. )


แจ้งเตือนเมื่อมีสินค้า

ไม่มีคะแนนสะสมสำหรับสินค้านี้เพราะมีส่วนลดแล้ว

สั่งซื้อสินค้า กรุณาติดต่อฝ่ายขาย

UPS Zircon ZC-MP 10kVA 1:1p ทำให้ใหญ่สุด

InputPhaseSingle phase & Ground
Rated Voltage220/230VAC +/- 25%
Voltage Range140-290V*
Frequency Range40Hz-70Hz (settable) +/- 0.1%
Power Factor>0.99
Current THDi5% at 100% non-linear load
Bypass Voltage RangeMax, voltage; +5% (optional +5%, +10%, +25%)
 Min. voltage:-45% (oplional -20%,-30%, -45%)
 Frequency protection range: +/-10%
ECO Rangesame as the bypass
Hamonic Current<5% ( 100% non-linear load )
OutputPhaseSingle phase & Ground
Rated Voltage220/230VAC
Power Factor0.9
Voltage Regulation+/- 1%
Frequency - Utility Mode1%,2%,4%,5%,10% of the rated frequency (optional)
                  - Battery Mode50Hz +/- 0.1% Hz
Crest Factor3:01
THD< 2% with Linear Load
 < 5% with non  Linear Load
Wave FormPure Sine Wave
EfficiencyAC Mode (full load)Up to 90%
Battery Mode (full load)>88%
ECO Mode (tull load)>94%
BatteryVoltage192/216/240 Vdc
Capacity (Standard unit)12V/9Ah
Backup Time 15-30 min (Depend on load), Estimated remaining time display on the LCD
Recharge Time to 90%4-6 Hours
Charging Current -Standard1A (S), 6A (H)
Battery Number16/18/20 pcs (Settable)
Battery SocketAnderson Like PowerPole Modular Connectors
Transfer Time Utility to Battery; 0ms, Utility to Bypass <4ms
ProtectionOverload   - AC Mode108%+/-5%<Load<150%+/-5% exceed 30s, cut off and alarm,
 150%+/-5%<Load<200%+/-5% exceed 300ms, cut off and alarm
 108%+/-5%<Load<150%+/-5% exceed 30s, tranfer to bypass and alarm,
 150%+/-5%<Load<200%+/-5% exceed 300ms, tranfer to bypass and alarm"
                  - Batt. ModeLoad <100%-150%; 30S; Load >150%; 300ms then shutdown UPS completely
                  - Bypass ModeLoad >130%; 60S then shutdown output
Short CircuitHold Whole System
OverheatLine mode; Switch to Bypass; Battery Mode, shutdown UPS immediately
Battery LowAlarm and Switch off
Self-DiagnosticsUpon Power On and Software Control
EPOShutdown UPS immediately
BatteryAdvanced Battery Management
Noise SuppressionCompiles with EN962040-2
ALARMAudible & VisualLine Failure, Battery Low, Overload, System Fault
DisplayStatus LED & LCDLoad/Battery/Input/Output/Operating Mode information
Reading on the LCDLoad/Battery/Input/Output/Operating Mode information
PhysicalDimension(WxHxD) mm250 x 655 x 590
Weight (kg)70kg
Input Connectionhardwired
Output Connectionhardwired
External Battery ConnectionAnderson like PowerPole Modular connectors
CommunicationSmart RS232/USB PortSupport Windows Family, Linux, FreeDSB, etc.
InterfaceCommunication SlotSNMP Card (independent to RS232)
 R.J45Built-in Power Surge, Lightning Protection Device
EnvironmentOperating Temperature0 °C - 40 ° C
Storage Temperature-25  °C - 55 °C
Humidity0-95% (Non-condensing)
Altitude<1500 m. (derating while > 1500m)
Noise<55 dB (at 1 meter)
Safety Conformance CE
Industry StandardSafetyMeet IEC62040-1 GB4943
EMIIEC 62040-2
EMSIEC 62040-2
SurgeMeeting IEC62040-1 1.2/50uS-8/20uS 6kV/3kA
ISO9001 : 2015 , 14001 : 2015
 Warranty2 Year